• Kbsg Series Transformer Distribution Power Transformer Copper/Aluminum
  • Kbsg Series Transformer Distribution Power Transformer Copper/Aluminum
  • Kbsg Series Transformer Distribution Power Transformer Copper/Aluminum
  • Kbsg Series Transformer Distribution Power Transformer Copper/Aluminum

Kbsg Series Transformer Distribution Power Transformer Copper/Aluminum

Application: Power, Electronic
Phase: Three
Certification: ISO9001-2000
Usage: Power Transformer, Distribution Transformer
Standards: GB1094-1996; Jb/T10088-2004; GB/T6451-2008; Eqv I
Colour: Gray/Green
Customization:
Diamond Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
KBSG
Connection Sign
Yy0-D11
Tapping Range
± 5%, ± 2× 2.5%, ± 4&T
Voltage Grade
6kv, 10kv, 11kv, 13.8kv, 15kv
Voltage Regukation Mode
off Circuit Tap Changing or on Load Tap Changing
Cooling
Onaf
Frequency
50Hz; 60Hz
Type
Voltage Transformer
Trademark
JSM
Origin
China
HS Code
8504220000
Production Capacity
5000000 kVA/Year

Product Description

1) 22 years' manufacturing experience with three subsidiaries
2) Top 3 in China
3) Guarantee 30 years
4) Won tenders abroad
New type of S11, S11-M series three phased oil-immersed dis transformer, it is the renew products for saving energy
Low losses, energy saving
Core is in round form, multi-stage, and entire tilted three stages seaming and lapping structure
High and low voltage coils are winding with oxygen free copper coil. All high voltage coils are made with several layered bucket structure.
Oil-Immersed Transformer
Main characteristics of oil-immersed transformer:
1. High short-circuit resisting ability and fine mechanical performance
2. Low power consumption, low partial-discharge and low noise
3. No leakage, free of core and winding body lifting and no maintenance

1. Scientific computing method:
Adopt advanced computing software for electromagnetic heat and mechanical power to calculate the distribution of electromagnetic field and magnetic leakage, choose insulation tolerance and analyze wave process; The software is used for simulation design of plane and three-dimensiona dynamic model, which guarantees the products a reliable performance and a rational structure.

2. Rational array of structure:
According to the computing result, choose rational insulation structure, wire specification and magnetic flux density.
Adopt magnetic screen for oil tank. Calculate the natural vibration frequency of drawplate and iron core. Adopt multistage step lapped joint fully-oblique structure...
Reduce on-load power consumption and noise. Increase the short circuit resisting ability by adopting round bar and cardboard sleeve.
Reduce the partial-discharge by applying rounding process on the fringes of insulation parts and metal parts and metal parts inside the transformer.
2. Advanced processing methods:
Cut the iron core automatically, so the precision is high and the burr is very small.
Adopt non-overlapping upper yoke processing.
Apply double-H setting glue on the surface, Coil the wire vertically, and a numerical control tension device is needed.
Set-assemble is adopted for the body of transformer. Integral preassemble is adopted for the wire lead.
Full automatic control gas-kerosene drying process is adopted for the body of transformer. Preassemble is adopted for general assembly.

4. Perfect quality assurance system: Control the quality of products according to the ISO19001 quality standards.

5. Systematic data management: ERP&PDM data management programs are adopted during the whole process from sale to leaving factory
Technical Data of 10kV KBSG Series Dry Type Mining Explosion Isolation Dry Type Transformer
      Loss (kW)     Weight (kg) (mm) Gauge(mm)
Rated Capacity Voltage Group(kV) Connection                   (145) No-load current Impedance (L) (W) (H)  
(kVA) HV LV No-load Load % %   Dimension  
50 10± 5% 0.693/0.4 1.2/0.693  1.2          3.45 Yy0              (d11) 390 680 2.5 4 1400 2310 950 1295 600
100 560 1050 2.5 4 1800 2430 950 1430
200 950 1800 2 4 2200 2730 950 1525 600                  900
250 1100 2100 2 4 2500 2760 950 1540
315 1300 2500 1.8 4 2800 2800 980 1555
400 1500 3000 1.8 4 3000 2950 1050 1610
500 1750 3500 1.5 4 3300 2950 1050 1610
630 2000 4100 1.5 4 4400 3200 1080 1450
800 Yy0              (d11)  Dyn11 2300 5100 1.2 4 4700 3200 1080 1600
1000 2600 6100 1.2 4.5 5900 3200 1110 1675
1250 3100 7400 1 4.5 6500 3250 1125 1740
1600 3800 8500 1 5 8300 3450 1245 1830
2000 4500 9700 0.7 5 10900 3665 1250 1900
2500 5200 10800 0.7 5.5 13930 3780 1390 1900
3150 6100 12800 0.7 5.5 18350 3880 1390 1900
4000 7000 15000 0.7 6 20910 4210 1450 1900
(Note): (Tapping range of high voltage) ± 5%; ± 2× 2.5%, Frequency: 50Hz. The above data provides a reference only, movable transformer sustation the basis switch of the shape size  of transformer substation different but different.
 Kbsg Series Transformer Distribution Power Transformer Copper/Aluminum
Kbsg Series Transformer Distribution Power Transformer Copper/Aluminum
Kbsg Series Transformer Distribution Power Transformer Copper/Aluminum
Kbsg Series Transformer Distribution Power Transformer Copper/Aluminum

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Product Categories

Diamond Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
268
Year of Establishment
2011-01-14