• 11kv Sc (B) 10 Resin Insulation Power Transformer
  • 11kv Sc (B) 10 Resin Insulation Power Transformer
  • 11kv Sc (B) 10 Resin Insulation Power Transformer
  • 11kv Sc (B) 10 Resin Insulation Power Transformer
  • 11kv Sc (B) 10 Resin Insulation Power Transformer
  • 11kv Sc (B) 10 Resin Insulation Power Transformer

11kv Sc (B) 10 Resin Insulation Power Transformer

Phase: Three
Core: Shell-type Transformer
Cooling Method: Dry-type Transformer
Winding Type: Multi-winding Transformer
Certification: ISO9001-2000
Brand: Jsm
Samples:
US$ 2000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
11kv Sc (B) 10
Connection Method
Yyn0, Dyn11 or Others
Primary Voltage
11; 10.5; 10; 6.3; 6kv
Frequency
50 or 60 Hz
Secondary Voltage
0.4, 0.433kv
Type
Transformer
Production Capacity
50000PCS/Year

Product Description

1) 22 years' manufacturing experience with three subsidiaries
2) Authoritative type test report
3) KPLC's supplier in Kenya
3) IP54
Tech data of 10kv, 11kv SC(B)10 series resin insulation dry-type power transformer

1. Standards: GB1094-1996; JB/T10088-2004; GB/T10228-2008; EQV IEC726
2. Voltage Grade: 6, 10, 6.3KV, 11kV
3. Voltage Regukation Mode: Off circuit tap changing; On load tap changing
4. Tapping Range: ± 5%, ± 2× 2.5%, ± 4× 2.5% or others
5. Frequency: 50Hz; 60Hz
6. Phase: Three phase
7. Connection Sign: Yyn0, Dyn11 or others
8. Short Circuit Impedance: Standard impedance (For details see technical data sheet)
9. Max. Temperature: 120K
10. Cooling Method: ONAN or ONAF
11. Insulation Class: Grade F

Features:
High voltage coils are wrapped with Polyester enameled wires, filled with glass fiber, and then resin under vacuum condition. It becomes solid under high temperature. It equipped with high mechanical intensity, low discharge partly; Low voltage coils are wrapped with a whole piece of copper foil, with strong anti-shortcut capacity. The core is made of silicon steel. By reasonable choosing magnetic density, decrease the empty loading loss effectively
Fire protection, anti-explosion, and no pollution
Coil is free from humidity, low noise and well characteristic of heating dispersion
Low loss, energy saving, free from maintenance, small size, light, and easy for installation
Technical Data of 10kV  SCB(10) Cast Resin F Insulation Class Dry Type Power Transformer  
      Loss(kW)   Insulation Level Weight (kg) Outline Dimension (mm) Outline dimension with protective casing
Rated Capacity Voltage Group(kV) Connection Method     (120C) No-load current     (L) (W) (H) (L) (W) (H)
(kVA) HV LV No-load Load %          
10       0.135 0.305 4   130 600 450 490 900 800 850
20       0.17 0.595 3.5   170 600 450 560 900 800 850
30       0.195 0.705 2.6   330 620 450 650 1050 900 1000
50       0.27 0.995 2.2   380 620 450 750 1050 900 1000
63       0.33 1.21 2.2   440 750 500 760 1050 1000 1150
80       0.37 1.38 2.2   510 750 500 760 1100 1000 1150
100       0.4 1.57 2   590 750 500 890 1150 1100 1250
125 11   Dyn11 0.47 1.85 1.8   650 1060 600 1020 1350 1050 1200
160 10.5 0.4   0.545 2.13 1.8 F/F 780 1060 600 1060 1400 1050 1250
200 10   Yyn0 0.625 2.53 1.6   930 1060 710 1120 1450 1100 1350
250 6.3     0.72 2.76 1.6   1040 1100 710 1140 1500 1150 1400
315 6     0.88 3.47 1.4   1180 1150 710 1195 1500 1200 1450
400       0.975 3.99 1.4   1450 1260 870 1285 1600 1250 1600
500       1.16 4.88 1.4   1630 1290 870 1355 1600 1300 1650
630       1.345 5.87 1.2   1900 1450 870 1420 1800 1300 1700
630       1.3 5.96 1.2   1900 1500 870 1370 1850 1300 1650
800       1.52 6.955 1.2   2290 1550 870 1570 1900 1300 1800
1000       1.77 8.13 1.1   2700 1600 870 1665 1950 1300 1950
1250       2.09 9.69 1.1   3130 1680 1120 1765 2050 1350 2000
1600       2.45 11.73 1.1   3740 1750 1120 1860 2100 1400 2100
2000       3.32 14.45 1   4150 1770 1120 1865 2150 1500 2100
2500       4 17.17 1   4810 1870 1120 1950 2200 1500 2200
3150       5.14 22.5 0.8   5800 1950 1120 1900 2350 1600 2250
4000       5.96 27 0.8   7100 2100 1120 2050 2400 1600 2300
(Note): (Tapping range of high voltage) ± 5%; ± 2× 2.5%, Frequency: 50Hz.  
11kv Sc (B) 10 Resin Insulation Power Transformer
11kv Sc (B) 10 Resin Insulation Power Transformer
11kv Sc (B) 10 Resin Insulation Power Transformer
11kv Sc (B) 10 Resin Insulation Power Transformer
11kv Sc (B) 10 Resin Insulation Power Transformer
11kv Sc (B) 10 Resin Insulation Power Transformer
11kv Sc (B) 10 Resin Insulation Power Transformer
11kv Sc (B) 10 Resin Insulation Power Transformer
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Product Categories

Diamond Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
268
Year of Establishment
2011-01-14